STARTER ST400M-G PH & CONDUCTIVITY PORTABLE KIT MULTI-PARAMETER

Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature Waterproof Meter

Quick Overview

Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature Waterproof Meter

Availability: In stock

Only 1 left

Excl. Tax: NZ$2,730.00 Incl. Tax: NZ$3,139.50

Details

Multiparameter pH/ORP/EC/TDS/Salinity/DO/Pressure/ Temperature Waterproof Meter 

HI98194 is supplied with HI7698194 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.

pH Range

0.00 to 14.00 pH

pH Resolution

0.01 pH

pH Accuracy

±0.02 pH

pH Calibration

automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer

ORP Range

±2000.0 mV

ORP Resolution

0.1 mV

ORP Accuracy

±1.0 mV

ORP Calibration

automatic at one custom point (relative mV)

mV Range

±600.0 mV

mV Resolution

0.1 mV

mV Accuracy

±0.5 mV

EC Range

0 to 200 mS/cm (absolute EC up to 400 mS/cm)

EC Resolution

auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01

EC Accuracy

±1% of reading or ±1 µS/cm whichever is greater

EC Calibration

automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point

TDS Range

0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)

TDS Resolution

manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt):

TDS Accuracy

±1% of reading or ±1 ppm (mg/L), whichever is greater

TDS Calibration

based on conductivity or salinity calibration

Salinity (PSU) Range

0.00 to 70.00 PSU

Salinity (PSU) Resolution

0.01 PSU

Salinity (PSU) Accuracy

±2% of reading or ±0.01 PSU whichever is greater

Salinity (PSU) Calibration

based on conductivity calibration

Salinity (Seawater Sigma) Range

0.0 to 50.0 σt, σ₀, σ₁₅

Salinity (Seawater Sigma) Resolution

0.1 σt, σ₀, σ₁₅

Salinity (Seawater Sigma) Accuracy

±1 σt, σ₀, σ₁₅

Salinity (Seawater Sigma) Calibration

based on conductivity or salinity calibration

Resistivity Range

0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm

Resistivity Resolution

dependent on resistivity reading

Resistivity Calibration

based on conductivity calibration

Dissolved Oxygen Measurement Type

Polarographic

Dissolved Oxygen Range

0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)

Dissolved Oxygen Resolution

0.1%; 0.01 ppm (mg/L)

Dissolved Oxygen Accuracy

0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3

Dissolved Oxygen Calibration

automatic one or two points at 0 and 100% or one custom point

Dissolved Oxygen Temperature Compensation

automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F)

Barometric Pressure Compensation

automatic from 450 to 850 mmHg

Salinity Compensation

automatic from 0 to 70 g/L

Atmospheric Pressure Range

450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Atmospheric Pressure Resolution

0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Atmospheric Pressure Accuracy

±3 mm Hg within ±15% from calibration point

Atmospheric Pressure Calibration

automatic at one custom point

Temperature Range

Temperature Range

Temperature Resolution

0.01 K, 0.01 °C, 0.01 °F

Temperature Accuracy

±0.15 °C; ±0.27 °F; ±0.15 K

Temperature Calibration

automatic at one custom point

Temperature Compensation

automatic from -5 to 55 °C (23 to 131 °F)

Logging Memory

45,000 records (continuous logging or log-on-demand of all parameters)

Logging Interval

one second to three hours

Connectivity

USB to PC with HI9298194 Hanna software installed

Battery Type/Life

1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)

Environment

0 to 50°C (32 to 122°F); RH 100% (IP67)

Dimensions

185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)

Weight

400 g (14.2 oz.)

Additional Information

Country of Manufacture U.S.
Manufacturer HANNA INSTRUMENTS

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality
Value
Price